Uninterruptable Power Supplies (UPS) provide a secure and filtered source of AC power for all types of IT equipment. In the event of a prolonged utility power failure, systems can be shutdown gracefully preventing lengthy recovery processes upon power resumption.
Features:
- Floor standing (tower) UPS from
700W to 80KW
- Rack mounted UPS from 700W to 16KW
- Selection of battery sizes
- On Line UPS technology for
no-break switchover
- Full-time power conditioning
- Automatic bypass circuit
- Automatic battery management
- Ethernet communication with
server(s)
- Software for Solaris on SPARC, Solaris on X86, Linux and Microsoft Windows included
- Automatic system shutdown during
extended utility power failure
- UPS and power monitoring via GUI
or command line utility
- Support for multiple servers with
one or more UPS
- Site Survey* and installation**
included
- Onsite next day response warranty
- Sun maintenance options available
- Larger UPS, extended autonomies and generators available on
request
- RoHS compliant
* Site survey for 2100W and larger UPS.
** 700W
and 1400W tower UPS are customer installable (optional engineer
installation service available for hardware and first copy of
software).
UPS Sizing:
UPS sizing to
determine the UPS model required is essential in order to ensure
correct operation. An automated email-driven UPS sizing utility is
available; please email ups@uk.sun.com with subject "help" for operating instructions. Orders for
UPS can not be accepted without a "U Reference Number"
which can be obtained from the UPS sizing.
Site
Survey:
All 2100W and larger UPS above include a
pre-delivery site survey (by telephone or site visit depending upon
model) to determine the accessibility for delivery and installation
and that the electrical requirements of the UPS are met.
If
additional electrical work is needed prior to the installation of the
UPS, our representative will be pleased to quote for this at the time
of the survey. If the customer opts to carry out their own electrical
work as recommended by the survey, it will be the customer's
responsibility to ensure that the work is carried out to the relevant
standards.
If at UPS installation time it is found that the
recommendations of the site survey have not been carried out, or have
been carried out but do not meet the relevant standards, an extra
charge may be incurred.
Installation:
Floor
standing 700W and 1400W UPS are customer installable and include
documentation for this purpose - use the option UKT-UPS-INS for
engineer hardware and software installation (on a single
server/domain) of these UPS.
All other UPS include onsite
engineer installation between Mon to Fri during normal working hours.
Installations outside of normal working hours and at weekends may be
ordered using the UKT-UPS-OOHI-WE/WD product codes. Included with the
hardware installation is the engineer installation of a single copy
of the software on one server or domain. A software install option
for multiple servers and or domains is available using order code
GB-PS-UPSINSTALL. Installation will be performed during normal office
working hours, Monday to Friday excluding public holidays. Last
minute rescheduling of the installation by the customer may incur an
additional charge.
Please note that to prevent shipping
delays, the installation address details should be included with the
order for engineer installed UPS. Please contact Complementary
Products if it is not possible to provide this
information.
Connections:
All UPS include all necessary power cables and a single communication cable, up to the output power cable limits described below. For engineer installed UPS, additional output connections are available at cost during engineer installation.
- 700W and 1400W floor standing UPS: 4x IEC320 (the option UKT-UPS-5WAY-Z may be used to expand the IEC320 outlets by 4)
- 700W and 1400W rack mounted UPS: 2x (16A/32A IEC309 and/or 4-way BS 13A sockets)
- 2.1KW to 4.2KW UPS: 4x (16A/32A IEC309 and/or 4-way BS 13A sockets)
- 8KW to 16KW UPS: Up to 9x (16A/32A IEC309 and/or 4-way BS 13A sockets)
- 24KW or larger UPS: Up to 12x (16A/32A IEC309 and/or 4-way BS 13A sockets)
Server Communications:
The UPS communicates with the server(s) using Ethernet and requires to be allocated an IP address (a 5m UTP cable is included with each UPS). Please ensure that a network which connects with each server to be powered by the UPS is available for the UPS connection. Any network hardware must be powered by the UPS so that communications are maintained in the event of utility power failure. If only a single server (and single domain) is to be supported by the UPS, a cross-over Ethernet cable (order code UKT-UTP-CASCADE-Z) can be used to connect directly to a spare Ethernet port on the server.
Rack Mounting:
Rack mounted UPS are supported in all Sun racks and most third party racks (although compatibility with non-Sun racks can not be guaranteed). The rack mount kit is included with the UPS.
Accessories
and Options:
- UKT-UPS-5WAY-Z: 5 way IEC320 mains adapter for the 700W and 1400W tower UPS only. Increases IEC320 output connections by four. Includes all cables required – RoHS compliant.
- UKT-UPS-INS: Installation service for 700W and 1400W tower UPS only. Includes hardware install and install of one copy of the software (Mon to Fri, 09:00 to 17:30, excluding public holidays)
- GB-PS-UPSINSTALL: Sun engineer UPS software installation service for multiple Sun systems or multi-domain Sun servers (Mon to Fri, 09:00 to 17:30, excluding public holidays)
- UKT-UPS-OOHI-WD: Out of hours (Mon 17:30 to Fri 09:00) UPS installation option. Includes hardware installation and installation of one copy of the software.
- UKT-UPS-OOHI-WE: Out of hours (Fri 17:30 to Mon 09:00 and bank holidays) UPS installation option. Includes hardware installation and installation of one copy of the software.
Software:
- Supports stand-alone command line and Java GUI interfaces
- Automatic system shutdown on utility failure after specified period
- Automatic system shutdown on
battery low after utility failure
- Automatic initiation of customised
actions
- Automatic UPS shutdown and
start-up
- Broadcasting of messages to users
- User definable message contents
- User defined message frequency
- Logging for power system events
- Logging of UPS parameters and
alarms
- Real-time display of UPS load,
Battery charge, run time remaining
- Requires a UPS powered 10Base-T
network connection from each server or domain to the UPS
- Software licence allows the
software to be installed on as many servers as are powered by the
UPS
- Supports up to 16 UPS and 64
servers
- Installation of one copy of the
software included with all UPS except for 700W and 1400W tower
models
- The UPS Software is supported
under the following Operating Systems:
- Solaris on SPARC (version 2.6 and
above, GUI elements from Solaris 7 and JRE 1.2)
- Solaris on X86 (version 9 and
above)
- SuSE Linux (V8.0 and above)
- Red Hat Linux (V8.0 and above, RHES V2.1 and above)
- Microsoft Windows 98, NT, ME, 2000, 2003 and XP
Order Codes: (Usual lead time is 2 weeks)
| £575/H |
UKT-UPS-0K7W-08-Z
700W Tower UPS, 8' autonomy, user
installable – RoHS compliant |
| £815/H |
UKT-UPS-1K4W-10-Z
1400W Tower UPS, 10' autonomy, user
installable – RoHS compliant |
| £1,230/H |
UKT-UPS-1K4W-30-Z
1400W Tower UPS, 30' autonomy, user
installable – RoHS compliant |
| £1,540/H |
UKT-UPS-2K1W-08-Z
2100W Tower UPS, 8' autonomy –
RoHS compliant |
| £1,975/H |
UKT-UPS-2K1W-25-Z
2100W Tower UPS, 25' autonomy –
RoHS compliant |
| £3,300/H |
UKT-UPS-4K2W-08-Z
4200W Tower UPS, 8' autonomy –
RoHS compliant |
| £4,700/H |
UKT-UPS-4K2W-30-Z
4200W Tower UPS, 30' autonomy –
RoHS compliant |
| £6,400/H |
UKT-UPS-8K0W-10-Z
8KW Tower UPS, 10' autonomy –
RoHS compliant |
| £7,720/H |
UKT-UPS-8K0W-25-Z
8KW Tower UPS, 25' autonomy –
RoHS compliant |
| £7,750/H |
UKT-UPS-12K0W-10-Z
12KW Tower UPS, 10' autonomy –
RoHS compliant |
| £8,250/H |
UKT-UPS-12K0W-25-Z
12KW Tower UPS, 25' autonomy –
RoHS compliant |
| £8,750/H |
UKT-UPS-12K0W-40-Z
12KW Tower UPS, 40' autonomy –
RoHS compliant |
| £8,800/H |
UKT-UPS-16K0W-10-Z
16KW Tower UPS, 10' autonomy –
RoHS compliant |
| £9,300/H |
UKT-UPS-16K0W-20-Z
16KW Tower UPS, 20' autonomy –
RoHS compliant |
| £9,800/H |
UKT-UPS-16K0W-50-Z
16KW Tower UPS, 50' autonomy –
RoHS compliant |
| £12,000/H |
UKT-UPS-24K0W-10-Z
24KW Tower UPS, 10' autonomy –
RoHS compliant |
| £15,500/H |
UKT-UPS-24K0W-20-Z
24KW Tower UPS, 20' autonomy –
RoHS compliant |
| £17,000/H |
UKT-UPS-24K0W-40-Z
24KW Tower UPS, 40' autonomy –
RoHS compliant |
| £14,500/H |
UKT-UPS-32K0W-10-Z
32KW Tower UPS, 10' autonomy –
RoHS compliant |
| £17,500/H |
UKT-UPS-32K0W-20-Z
32KW Tower UPS, 20' autonomy –
RoHS compliant |
| £22,000/H |
UKT-UPS-32K0W-45-Z
32KW Tower UPS, 45' autonomy –
RoHS compliant |
| £20,750/H |
UKT-UPS-48K0W-10-Z
48KW Tower UPS, 10' autonomy –
RoHS compliant |
| £25,500/H |
UKT-UPS-48K0W-25-Z
48KW Tower UPS, 25' autonomy –
RoHS compliant |
| £29,500/H |
UKT-UPS-48K0W-36-Z
48KW Tower UPS, 36' autonomy –
RoHS compliant |
| £22,500/H |
UKT-UPS-64K0W-08-Z
64KW Tower UPS, 8' autonomy –
RoHS compliant |
| £29,000/H |
UKT-UPS-64K0W-20-Z
64KW Tower UPS, 20' autonomy –
RoHS compliant |
| £36,500/H |
UKT-UPS-64K0W-40-Z
64KW Tower UPS, 40' autonomy –
RoHS compliant |
| £30,750/H |
UKT-UPS-80K0W-10-Z
80KW Tower UPS, 10' autonomy –
RoHS compliant |
| £32,250/H |
UKT-UPS-80K0W-18-Z
80KW Tower UPS, 18' autonomy –
RoHS compliant |
| £39,250/H |
UKT-UPS-80K0W-35-Z
80KW Tower UPS, 35' autonomy –
RoHS compliant |
| £870/H |
UKT-UPS-0K7W-08R-Z
700W Rack Mounted UPS, 8' autonomy
– RoHS compliant |
| £1,110/H |
UKT-UPS-1K4W-10R-Z
1400W Rack Mounted UPS, 10'
autonomy – RoHS compliant |
| £1,470/H |
UKT-UPS-1K4W-30R-Z
1400W Rack Mounted UPS, 30'
autonomy – RoHS compliant |
| £1,560/H |
UKT-UPS-2K1W-08R-Z
2100W Rack Mounted UPS, 8'
autonomy – RoHS compliant |
| £1,970/H |
UKT-UPS-2K1W-25R-Z
2100W Rack Mounted UPS, 25'
autonomy – RoHS compliant |
| £3,300/H |
UKT-UPS-4K2W-08R-Z
4200W Rack Mounted UPS, 8'
autonomy – RoHS compliant |
| £4,700/H |
UKT-UPS-4K2W-30R-Z
4200W Rack Mounted UPS, 30'
autonomy – RoHS compliant |
| £6,600/H |
UKT-UPS-8K0W-10R-Z
8KW Rack Mounted UPS, 10' autonomy
– RoHS compliant |
| £8,100/H |
UKT-UPS-8K0W-25R-Z
8KW Rack Mounted UPS, 25' autonomy
– RoHS compliant |
| £8,000/H |
UKT-UPS-12K0W-8R-Z
12KW Rack Mounted UPS, 8' autonomy
– RoHS compliant |
| £8,850/H |
UKT-UPS-16K0W-8R-Z
16KW Rack Mounted UPS, 8' autonomy
– RoHS compliant |
| £105/H |
UKT-UPS-5WAY-Z
5 way IEC mains expansion adapter for
the 700W and 1400W tower UPS – RoHS compliant |
| £290/H |
UKT-UPS-INS
Installation of hardware and one copy of
the software for 700W and 1400W tower UPS only (already included
with all other UPS) |
| £1,100/H |
UKT-UPS-OOHI-WD
Out of Hours Installation. Monday to
Thursday between the hours of 17.30 to 09.00 |
| £2,175/H |
UKT-UPS-OOHI-WE
Out of Hours Installation. Between
Friday 17.30 and Monday 09.00 and on Bank Holidays |
| £1,200/D |
GB-PS-UPSINSTALL
Sun Installation Service for UPS
Software on Multiple Sun Systems and/or Multi-Domain Servers |
Larger UPS, longer autonomies and generators can also be
supplied. Please contact Complementary Products for details. |